Thermal Expansion Calculator
Find how much a part lengthens or shortens when the temperature changes, the gap to leave, and the stress and force if it can't move.
- Free
- No sign-up
- Runs in your browser
Inputs
Result
Change in length
3.6mm
- Final length
- 6.0036m
- Recommended gap
- 4 mm
Formula
ΔL = α × L × ΔT
Reference coefficients: they vary with the alloy or mix. Edit them if you have the datasheet.
Cold and hot part, difference exaggerated
+ 3.6 mm
Same length and temperature change in each material
| Material | α | Change | |
|---|---|---|---|
| Rigid PVC | 54 | 16.2 mm | |
| Aluminum | 23 | 6.9 mm | |
| Brass (C26000) | 19 | 5.7 mm | |
| Stainless steel 304 | 17 | 5.1 mm | |
| Copper | 17 | 5.1 mm | |
| Carbon steel | 12 | 3.6 mm | |
| Concrete | 10 | 3 mm | |
| Glass | 9 | 2.7 mm |
Results are estimates and should be verified for critical engineering or manufacturing applications.
How it works
Choose the material, the length and the temperature range. The calculator gives the change in length, the final length, the gap to leave and a comparison with other materials.
If the part can't move, switch to Blocked and enter its section to see the stress and force that appear. That is the ideal case of full restraint and doesn't replace a structural calculation: real joints give way, and parts can yield or buckle first.
Formula
- ΔL (mm) = α (10⁻⁶/°C) × L (m) × ΔT ÷ 1000
- Stress if fully blocked (MPa) = E × α × 10⁻⁶ × ΔT
- Force (N) = Stress × Area (mm²)
- Square tube area = Side² − (Side − 2 × Wall)²
Example
A 6 m gate in a 50 × 50 × 3 steel tube, from 0 to 50 °C
- 1ΔL = 12 × 6 × 50 ÷ 1000 = 3.6 mm, so leave a 4 mm gap
- 2Stress if blocked = 200,000 × 12 × 10⁻⁶ × 50 = 120 MPa
- 3Area = 50² − 44² = 564 mm²
- 4Force = 120 × 564 = 67,680 N = 67.7 kN
It grows 3.6 mm and, if fully blocked, would push with about 6.9 tonnes.
Assumptions, sources and review
Assumptions and limitations
- ΔL = α × L × ΔT, a linear approximation valid for ordinary temperature ranges.
- α (10⁻⁶/°C): carbon steel 12, stainless 304 17, aluminum 23, copper 17, brass 19, concrete 10 (about 7 to 11 by aggregate), soda-lime glass 9, rigid PVC 54 (published values go from about 50 up to 110).
- E (MPa): steel 200,000 (Eurocode uses 210,000), stainless 193,000, aluminum 69,000, brass C26000 110,000, concrete C30/37 33,000, glass 70,000. Copper 117,000 is the commonly published value, not confirmed in an open primary source.
- Recommended gap = the change in length rounded up. It doesn't add installation tolerance.
- Restrained mode is the ideal case of a bar fully blocked along its axis (σ = E × α × ΔT), with no yielding, buckling or joint movement. It doesn't replace a structural calculation.
- Concrete and glass can crack before reaching the calculated stress. PVC has no restrained mode because its stiffness falls with temperature and its stress relaxes over time.
Sources
- EN 1993-1-1, cl. 3.2.6: steel, E and thermal expansion
- EN 1991-1-5, Table C.1: expansion coefficients of construction materials
- EN 1992-1-1, Table 3.1 and cl. 3.1.3: concrete modulus and expansion
- NIST Center for Neutron Research — Reference tables (expansion of metals)
- OpenStax, University Physics Vol. 2 — Thermal expansion and thermal stress
- MatWeb data sheet — 304 stainless steel
- ASM/MatWeb data sheet — Aluminum 6061-T6
- Concast — C26000 brass (CDA properties)
- AGC — Planibel glass technical data sheet
- PVC Pipe Association — Thermal expansion of PVC pipe
The formula and the worked example on this page are checked by automated tests in Oxenly's code.
Last reviewed on November 22, 2026 by Diego Urtado.
Found an error? Report itFrequently asked questions
How much gap should I leave?
At least the calculated change, rounded up, measured for the temperature at which you install. If you fit the part on a hot day, most of the movement will be shrinkage; on a cold day, growth.
Why does aluminum move more than steel?
Its expansion coefficient is about twice as high. The same 6 m piece over 50 degrees changes 6.9 mm in aluminum and 3.6 mm in steel.
Does the force depend on the length?
No. In a fully blocked part, the stress depends on the material and the temperature change, and the force on the section. Length changes how much it would move, not how hard it pushes.
Can I use the blocked result to size a structure?
No. It's an ideal case with no yielding, buckling or joint movement. For anything structural, consult an engineer.
Keep going