Skip to content
Fabrication

Tap Drill Size Chart & Calculator

Find the drill to use before tapping and the clearance hole for metric, UNC and UNF threads, with a printable workshop chart.

  • Free
  • No sign-up
  • Runs in your browser

Inputs

Mode
Thread

For example M8, M10x1.25, 1/4-20 or #8-32.

Result

Tap drill · M8 × 1.25

6.8mm

8 − 1.25 = 6.75 mm

Pitch
1.25mm
Thread engagement (approx.)
74%
Clearance hole, close fit
8.4 mm
Clearance hole, medium fit
9.0 mm

Formula

Tap drill = Diameter − Pitch

Reference values. Check the tap maker's chart for hard materials, blind holes and critical parts. Thread % uses 100% = 1.299 × pitch. Machinery's Handbook uses another basis, where the same hole reads higher.

Pro feature

Tap drill chart

Thread system
ThreadPitch / TPITap drill (mm)Drill sizeClose fit (mm)Medium fit (mm)
0.41.6—2.22.4
0.452.05—2.72.9
0.52.5—3.23.4
0.73.3—4.34.5
0.84.2—5.35.5
15.0—6.46.6
1.256.8—8.49.0
1.58.5—10.511.0
1.7510.2—13.013.5
212.0—15.015.5
214.0—17.017.5
2.515.5—19.020.0
2.517.5—21.022.0
321.0—25.026.0

Results are estimates and should be verified for critical engineering or manufacturing applications.

How it works

Type the thread, such as M8, M10x1.25 or 1/4-20, to see the drill to use before tapping and the clearance hole that lets the screw pass freely. Below is the full chart for metric coarse, metric fine, UNC and UNF, ready to print for the workshop wall.

If your thread isn't in the chart, use “Other thread” and enter its diameter and pitch. These are reference values: for hard materials, blind holes or critical parts, check the tap maker's chart.

Formula

  • Tap drill = Diameter − Pitch
  • Pitch in mm (inch threads) = 25.4 ÷ Threads per inch
  • Thread % = (Diameter − Drill) ÷ (1.299 × Pitch) × 100

Example

Tapping a coarse M8 thread

  1. 1Diameter 8 mm, pitch 1.25 mm
  2. 2Drill = 8 − 1.25 = 6.75 mm
  3. 3Nearest commercial drill: 6.8 mm
  4. 4Clearance hole for an M8 screw: 8.4 mm close fit, 9 mm medium fit

Drill at 6.8 mm, then run the M8 tap.

Assumptions, sources and review

Assumptions and limitations

  • Tap drill = diameter − pitch, rounded to the nearest 0.1 mm. Threads in the chart use the published drill, such as 10.2 for M12 and 2.05 for M2.5.
  • Inch threads show the published fraction, number or letter drill. Outside the chart, the closest drill is used.
  • Metric clearance holes follow ISO 273. Inch clearance holes follow ASME B18.2.8, where medium is its normal fit.
  • Thread percentage uses 100% = 1.299 × pitch. Machinery's Handbook uses 1.0825 × pitch, where a diameter-minus-pitch hole reads about 92% instead of 77%.
  • Reference values for cut taps. Check the tap maker's chart for form taps, hard materials, blind holes and critical parts.

The formula and the worked example on this page are checked by automated tests in Oxenly's code.

Last reviewed on November 22, 2026 by Diego Urtado.

Found an error? Report it

Frequently asked questions

What size drill do I use for an M8 tap?

For coarse M8 (1.25 mm pitch), a 6.8 mm drill. For fine M8 (1 mm pitch), a 7 mm drill.

What's the difference between a tap drill and a clearance hole?

A tap drill hole is smaller than the screw because the tap cuts the threads into its walls. A clearance hole is slightly larger than the screw so it passes through without threading.

When should I use a close or a medium fit?

A close fit locates the part better but needs well-aligned holes. A medium fit leaves more room when there are several screws or parts are assembled on site.

What does thread percentage mean?

It shows how much of the full thread is formed. Here, 100% equals 1.299 times the pitch, and the diameter-minus-pitch rule gives about 77%. Other handbooks use a different basis, so the number can change for the same hole.

Why does M12 use a 10.2 mm drill if 12 minus 1.75 is 10.25?

Common drills come in 0.1 mm steps, and published charts use 10.2 for this thread.

Keep going